Deyan

Members
  • Content

    798
  • Joined

  • Last visited

  • Days Won

    1
  • Feedback

    0%

Everything posted by Deyan

  1. I have so many questions.... Why is weight important to you? For BASE jumping I kinda understand since you will have to hike with it (sometimes for hours). For skydiving though...?! If you want to cut weight from you future rig, forget about stuff like spacer foam, hip/chest rings, Cordura and you'll probably save about 6-700 grams. If the weight is the only factor you are looking at, the undisputed world champion of light weight rigs is a Power Racer. I believe the smallest I ever saw was 275/275 and it was like 6.5 kg with canopies...
  2. I was referring to Vigil's PSB-8 Vigil R&D has confirmed that the electronics worked correctly and fired the cutter, but because of the absence of the knife blade, the closing loop could not be cut.
  3. IMO, it's a combination between the cap size, the side flaps being sewn too far in the corner, the pin cover stiffener too thick and tucked too far in. I've measured 70 mm being tucked in on one of the NexGen sizes. It's ridiculous! Being "freefly friendly" is important, but "reserve deployment friendly" is importanter. Pardon my French Interesting fact is that Aerodyne has 2 cap size RPCs (I believe 5 and 6 inches) and 2 types of cap shapes (flat one and concave), but unlike UPT they haven't published (to my knowledge) a guide which cap size goes into which container size.
  4. Even if they were "full fit", but inside the allowed sizes, that's not supposed to happen.I know the rigger who packed it and I'm willing to bet that the canopies are the correct size, the loop was the correct length and treated with silicon. Now, you can say that the picture doesn't represent "a real life scenario" because the person on the picture doesn't wear the legstraps. To which I would answer, I'll never jump a rig where the reserve deployment depends on how tight you have your legstraps.
  5. Yes. Because they were designed, tested and certified before Sept 2012. OM-7 is 4 years old canopy. If it was TSO tested it would have been C23f. The label says C23d which makes me believe it was a labeling error rather than the canopy actually being TSO certified.
  6. My money is on labeling error. If it was TSO'd, would have been C23f and not "d"
  7. The guy said he will make it. You don't need to remind him every two years....
  8. As much as I would like to agree with Jerry and BIGUN, the reality is sometimes manufacturer's rigger gets it wrong. For example, the manufacturer is located in a place where the humidity is very low. Low humidity could drastically increase the packing volume. You are jumping in very high humidity. Or, the manufacturer doesn't have hands on experience with certain model/size canopy and their advice is based on "we guess" rather than "we know for sure". And yes, this have happened to me on several occasions with different manufacturers. If I were you, I'd listen to your dealer. That's the person you've chosen to spend your money with and he/or she will be dealing with you if you end up not being happy at the end. With other words, your dealer is more interested in you being happy than the manufacturer. For that manufacturer, you are just a name on a .pdf file. Now I'm curious what rig/canopy combo you are interested in?!
  9. Here are some questions for you. What model was the rig? Does it have a free fly tuck tab on the handle? If yes, was it tucked in? Did you get a proper briefing when you rented it? The reason I'm asking is, most modern rigs will come with some kind of freefly secure handle. Sometimes that handle will require a slightly different angle to be pulled out, or just more force. If you were not aware of it, I can see why you thought you were having a hard pull. Packing the PC in the pocket could also make a difference in the pull force. If I have to make a guess based on your story, I'd say there's nothing wrong with the gear. I spend about 20-30 min briefing people how to check and use the gear they rent from me. I explicitly tell them about the free fly tab and how to avoid a hard pull.
  10. I have them, and can also make you a pair! However, I HIGHLY recommend you get rid of the reversed 3 ring risers. Here's why! https://www.youtube.com/watch?v=z9RHMQZTSGQ
  11. TSO is useless for that exact reason. You could certify something, then change it as many times as you wish as long as you log it as a "minor change". Vector Micron from February 2022 is exact same rig like 2 pinned Wonderhog from 1977 ..... In the eyes of the FAA
  12. How about you are unconscious and your AAD fires..... because of your body position only ONE raiser cover opens.... How would you like a spinning line twist under your reserve?
  13. What about the lockups after the ripcord pull? How is the cutter relocating going to fix those? Are you planing on changing the RPC cap to concave in order to accommodate for the extra thickness of the cutter? The rigs after the modification look like shit by the way.
  14. Hi Eric, I've received a statement from Pal Bergan saying :" All ground tests by pulling the reserve ripcord were successful." So which one is it? I find it strange that almost 2 months later they haven't identify the problem and came up with a solution.
  15. Try nancy at plabsinc dot com
  16. So I just checked that FORS you are talking about and it looks like they took the design of Eric Fradet and made it more complicated. (maybe to avoid paying royalties).
  17. PD won't do that. One, because of liability and second because every company has their own standards for acceptable permeability and measuring procedures. I doubt PS has shared their standards with PD.
  18. That's correct. However those loops don't fail that easily ! https://www.youtube.com/watch?v=9ruUZaTn_4M
  19. That will make sense if PIA was about sport skydiving.
  20. Properly manufactured risers don't fail at the grommet. They fail between the middle and the small ring. Most manufacturers have the RSL ring integrated in the confluence wrap
  21. You think the site is impressive...? You should visit their factory in Germany if you have the chance..... That's impressive!!
  22. There we go.....another brand war. For me there's one AAD brand. CYPRES!!! It's very simple. Get the number of units made, divide it by the number of Service Bulletins. That number should give you an idea of how likely is that the "maintenance free" will turn into "I can't jump in the middle of the season" maintenance. By the way, my CYPRES just came back from voluntarily maintenance. Just as a side note: Can anyone show me a 20 years old Vigil or 15 years old M2? The expected lifetime, doesn't always match the real lifetime.
  23. To me it looks like self induced line twist. You should stop pulling on your risers at line stretch. You might get away with doing that on a Sabre 2/3, Safire like canopies, but on higher performance canopies, you will "get bitten". How many jumps you have in total, and how many on this canopy ?